Model | ISL.T_5000W
| ISL.T_6000W
| ISL.T_8000W
| ISL.T_10000W
|
Efficiency | ||||
Max.effificiency (PV to AC) | 98.2% | 98.2%
| 98.4%
| 98.4%
|
Eur.effificiency (PV to AC) | 97.2% | 97.2%
| 97.9%
| 97.9%
|
Max.effificiency (BAT) | 98.0%
| 98.0%
| 98.0%
| 98.0%
|
Input(PV) | ||||
MAX PVPower(W) | 8000
| 9000
| 12000
| 15000
|
Max PV voltage (V) | 1000
| 1000
| 1000
| 1000
|
Max input current (input A/input B) (A) | 15/22
| 15/22
| 30/22
| 30/22
|
Max short current (input A/input B) (A) | 20/30
| 20/30
| 40/30
| 40/30
|
MPPT voltage range (V) | 160-950
| |||
No.of MPPT trackers | 2
| |||
String per MPP tracker | 1+1 | 2+1 | ||
Input (BAT) | ||||
Compatible battery type | Lithium-ion/Lead-acid | |||
Nominal battery voltage (V) | 200-600
| |||
Battery voltage range (V) | 150-600
| |||
Max. charge/discharge current (A) | 25/25
| 25/25
| 2*25/2*25
| 2*25/2*25
|
Max. charge/discharge power (W) | 8000/5200
| 9000/6300
| 12000/10500
| 15000/10500
|
Lithium battery charge curve | Self-adaption to BMS | |||
Output (Grid) | ||||
Nominal AC output power (W) | 5000
| 6000
| 8000
| 10000
|
Max. AC output apparent power (VA) | 5500
| 6600
| 8800
| 10000
|
Max.AC output power (PF=1) (W) | 5500
| 6600
| 8800
| 10000
|
Max. AC output current (A) | 3*8.3
| 3*10
| 3*13.3
| 3*15.2
|
Rated AC voltage (V) | 380/400V
| |||
AC voltage range (V) | 277-520 (adjustable)
| |||
Rated gird frequency (Hz) | 50/60 | |||
AC frequency range (Hz) | 45-55/55-65 (adjustable) | |||
Grid connecion | Three phase
| |||
Power factor | > 0.99 @rated power (adjustable 0.8 LG -0.8 LD) | |||
THDI | <3% | |||
Output(Back up) | ||||
Nominal output voltage (V) | 380/400V
| |||
Nominal output frequency (Hz) | 50/60 | |||
Nominal output power (W) | 5000
| 6000
| 8000
| 10000
|
Nominal output current(A) | 3*7.6
| 3*9.1
| 3*12.2
| 3*15.2
|
Transfer time (ms) | 10(typ) / 20(max) | |||
THDV | <3 (R Load), 5 (RCD Load)
| |||
Protection | ||||
Anti-islanding protection | Support
| |||
AC overcurrent protection | Support
| |||
AC short circuit protection | Support | |||
AC over-voltage protection | Support | |||
Surge Arrester | DC Type2, AC Type2
| |||
Insulation detection | Support | |||
GFCI
| Support | |||
AFCI
| Optional
| |||
RSD
| Optional
| |||
General | ||||
Max. operation altitude (m) | 4000 | |||
Noise emission (dB) | ||||
Ingress protection degree | IP65 | |||
Operating temperature range (℃) | -25~45
| |||
Relative humidity (%) | 0~100 | |||
Cooling concept | Natural Cooling | |||
Mounting | Wall bracket | |||
Dimensions (W*H*D) | 450mm*550mm*175mm
| |||
Weight (kg) | 20 | 25 | ||
PV connection way | MC4 / H4
| |||
Battery connection way | Dedicated DC connector | |||
HMI & COM | ||||
Display | LED+APP (Bluetooth) | |||
Communication interface | BMS (CAN/RS485), WiFi/GPRS/4G/Ethernet (optional), DI (DRM/RCR) / Meter (RS485), 1*DO, USB (Firmware upgrade) | |||
Certification | ||||
Grid | IEC 61727, IEC 62116, EN 50549-1, VDE 4105, AS 4777, CEI 0-21, G98 | |||
Safety | IEC62109-1&2, IEC62040-1, IEC62477-1 | |||
EMC | IEC/EN 61000-6-3, IEC 61000-3-11, IEC 61000-3-12 | |||
Warranty (years) | 5/10 (optional) |
Remarks:
◎The range of output voltage and frequency may vary depending upon different grid codes.
◎Specififications are subject to change without advance notice.