Smart Power Export

Management System


The Solenso Smart Power Export Management can intelligently control the output power of the photovoltaic system, and maximize the user’s power generation pro its without violating grid export regulations. At the same time, this system can also accurately display the power and production of the photovoltaic system with the measuring meter, so that users can trade the PV production online according to data on Solenso Cloud.

In Solenso Export Management solution, Solenso gateway DTU-SLS and additional meter (CT optional) are necessary. In the case of export limitation, the meter can be installed at the load side or the grid side. As shown below, the gateway DTU will dynamically adjust the PV power production according to the export power or load consumption as measured by the meter, so that the export power does not exceed the preset limit. To display the PV production in an accurate way, the meter needs to be installed at the output of the PV system to enable the user to get the PV power production remotely

System Composition

DTU-SLS

As the control center of export management solution, DTU receives data from the meter and adjusts the output power of the microinverters.

Single-phase electric meter(Via Current Transformer)

Single- phase electric meter can be connected to the circuit and used to measure the PV power production, load consumption and export power. When the meter cannot be directly connected to the circuit or the system capacity is a little higher, a single-phase meter with the external current transformer is preferred.

Suitable for single-phase power grid

Three-phase electric meter (Via Current Transformer)
Three-phase electric meter can be connected to the circuit and used to measure the PV power production, load consumption and export power. When the meter cannot be directly connected to the circuit or the system capacity is a little higher, a three-phase meter with the external current transformer is preferred.

Suitable for three-phase and split-phase power grid

   Model (Meter)

DDSU666

DTSU666

   Power Supply

   Grid type

1P2W

3P4W

   Input voltage (phase voltage)

176 Vac-288 Vac

   Power consumption (W)

≤1.5

   Measuring Range


   Phase voltage

176 Vac-288 Vac

   Current (A)

0-80

0-100/300/6001

   Measuring Accuracy


   Voltage

±0.5%

±0.5%

   Current/Power

±0.5%

±1%

   Energy

±0.5%

±1%

   Communication


   Interface

RS485

   Communication protocol

Modbus-RTU

   Mechanical Data


   Wiring type

Via-CT1

   Ambient temperature range (℃)

-25 to 55

   Dimensions (W×H×D mm)

36 x 100 x 65.5

72 x 100 x 65.5

   Mounting type

DIN35 Rail


*1:Needs to be used with the current transformers provided by Solenso.

Model (CT)

CT-100A/5A-1m

CT-300A/5A-1m

CT-600A/5A-1m

Electrical Speci ication

Rated primary current (A)

100

300

600

Rated secondary current (A)

5

Accuracy class

2%@10%Irated

1%@5%Irated

1%@5%Irated

Measuring range

5%Irated-120%Irated

Working frequency (Hz)

50/60

Mechanical Data

Thread

Single turn

Install

Buckle

Ambient temperature range (℃)

-25 to 65

Dimensions(W×H×D mm)

52 x 66 x 34

52 x 66 x 34

67 x 88.5 x 47

Conductor length (m)

1