Model | ISL _4.6kW-60 | ISL_4.6kW-120 | ISL_5kW -60 | ISL_5kW-120 | ISL_6kW-60 | ISL_6kW-120 |
Efficiency | ||||||
Max.effificiency (PV to AC) | 97.3% | |||||
Max.effificiency (BAT to AC) | 94.0% | |||||
Input(PV) | ||||||
MAX PVPower(W) | 9000 | |||||
Max PV voltage (V) | 550 | |||||
Max input current (input A/input B) (A) | 15/15 | |||||
Max short current (input A/input B) (A) | 20/20 | |||||
Start operating voltage(V) | 90 | |||||
MPP voltage range @full load (M) | 200-480 | 200-480 | 200-480 | 200-480 | 230-480 | 230-480 |
No, .of MPPT trackers | 2 | |||||
String per MPP tracker | 1 | |||||
Input (BAT) | ||||||
Compatible battery type | Lithium-ion/Lead-acid | |||||
Nominal battery voltage (V) | 48 | |||||
Battery voltage range (V) | 40-60 | |||||
Max. charge/discharge current (A) | 60/60 | 120/120 | 60/60 | 120/120 | 60/60 | 120/120 |
Max. charge/discharge power (W) | 3000/3000 | 5000/5000 | 3000/3000 | 5000/5000 | 3000/3000 | 6000/6000 |
Lithium battery charge curve | Self-adaption to BMS | |||||
Output (Grid) | ||||||
Nominal AC output power (W) | 4600 | 4600 | 5000 | 5000 | 6000 | 6000 |
Max. AC output apparent power (VA) | 4600 | 4600 | 5500 | 5500 | 6000 | 6000 |
Max.AC output power (PF=1) (W) | 4600 | 4600 | 5500 | 5500 | 6000 | 6000 |
Max. AC output current (A) | 22 | 22 | 25 | 25 | 27.2 | 27.2 |
Rated AC voltage (V) | 220 | |||||
AC voltage range (V) | 150-300 (adjustable) | |||||
Rated gird frequency (Hz) | 50/60 | |||||
AC frequency range (Hz) | 45-55/55-65 (adjustable) | |||||
Grid connecion | single phase | |||||
Power factor | > 0.99 @rated power (adjustable 0.8 LG -0.8 LD) | |||||
THDI | <3% | |||||
Output(Back up) | ||||||
Nominal output voltage (V) | 230 | |||||
Nominal output frequency (Hz) | 50/60 | |||||
Nominal output power (W) | 3000 | 4600 | 3000 | 5000 | 3000 | 6000 |
Nominal output current(A) | 13 | 20 | 13 | 21.7 | 13 | 26 |
Transfer time (ms) | 10(typ) / 20(max) | |||||
THDV | <3% @100% R Load | |||||
Protection | ||||||
Protection category | Class I | |||||
DC switch | Support | |||||
Anti-islanding protection | Support | |||||
AC overcurrent protection | Support | |||||
AC short circuit protection | Support | |||||
DC reverse connection | Support | |||||
Surge Arrester | DC Type ll AC Type ll | |||||
Insulation detection | Support | |||||
Leakage current protection | Support | |||||
PV overvoltage category | II | |||||
AC overvoltage category | III | |||||
General | ||||||
Max. operation altitude (m) | 4000 | |||||
Noise emission (dB) | <35 | |||||
Ingress protection degree | IP65 | |||||
Operating temperature range (℃) | -25~60 | |||||
Relative humidity (%) | 0~100 | |||||
Cooling concept | Natural Cooling | |||||
Mounting | Wall bracket | |||||
Dimensions (W*H*D) | Natural Cooling | |||||
Weight (kg) | 20 | 25 | 20 | 25 | 20 | 25 |
PV connection way | 515*450*175mm | |||||
Battery connection way | Dedicated DC connector | |||||
AC connection way (grid & back up) | Dedicated AC connector | |||||
HMI & COM | ||||||
Display | LED+APP | |||||
Communication interface | RS485/CAN(for BMS), RS485, USB, DRM/RS485 (for Meter), Optional: WiFi/GPRS/Ethernet | |||||
Certification | ||||||
Grid | VDE-AR-N4105, IEC 61727/62116, AS 4777.2, EN 50549-1 | |||||
Safety | IEC62109-1&2, IEC62040-1, IEC62477-1 | |||||
EMC | IEC61000-6-2/3 | |||||
Warranty (years) | 5/10 (optional) |